- Производитель:
- Roche
Comparison of Lumi-Light Substrate and Lumi-Light PLUS Substrate
Lumi-Light Substrate Lumi-LightPLUS Substrate
Sensitivity 10-50 pg antigen 1-5 pg antigen
Pimary Antibody Dilution Dilute up to 10-fold more compared to colorimetric detection Dilute up to 100-fold more compared to colorimetric detection
Signal Stability >3 hours (enhance signal with a 30-minute incubation) > 9 hours (enhance signal with a 30-minute incubation)
Number of tests: The reagent is sufficient for 10 blots, each with a size of 10 cm x 10 cm.
Sensitivity: Depending on the affinity of the primary antibody, 1 - 5 pg of antigen can be detected in research studies.
Storage/stability: The Lumi-LightPLUS substrate components are stable at +2 to +8°C until the expiration date printed on the label. Components are shipped at +15 to +25°C.
Lumi-LightPLUS Western Blotting Substrate is for the chemiluminescent detection of antigens blotted on membranes using horseradish peroxidase-conjugated secondary antibodies. It can be used for very sensitive detection of any antigen blotted on a PVDF Western Blotting Membrane or nitrocellulose membrane.
Lumi-LightPLUS Western Blotting Substrate is suited for high-sensitivity western blotting, especially when quantification is required. The chemiluminescent signal persists for more than 9 hours, allowing multiple exposures to be taken.
Features and Benefits
- Detect rare proteins. Detect antigen in the range of 1 - 5 pg.
- Take multiple exposures. The signal is stable for more than nine hours after substrate addition.
- Save sample material. Lumi-LightPLUS substrate detects less than 5 pg-amounts of antigen.
- Save valuable resources. Dilute primary antibody 10- to 100-fold more than with colorimetric detection systems.
- Benefit from easy preparation. Simply mix the two Lumi-Light components in a 1:1 ratio.
Packaging
1 kit containing 2 components
Quality
Each lot is function tested using mouse or rabbit primary antibodies.
Preparation Note
Stabilizers: proteinaceous stabilizers
Working concentration: The working concentration of conjugate depends on application and substrate.
The following concentrations should be taken as a guideline:
- Dot blot: 50 mU/ml
- ELISA: 25 mU/ml
- Western blot: 50 mU/ml
Working solution: Preparation of Additional Reagents and Solutions
The table inside the package insert describes the preparation of working solutions. Volumes are designed for a membrane of 10x10 cm. If larger membranes are used, volumes have to be scaled up. For reproducible results, equilibrate all solutions to room temperature before use.
Note: Do not use Azide to stabilize the solutions against microbial growth, as azide irreversibly inhibits horseradish peroxidase.
packaging | pkg of 100 mL (1,000 cm2 membrane) |
Quality Level | 100, |
Торговая марка | Roche |
shipped in | wet ice |
storage temp. | 2-8°C |
RIDADR | NONH for all modes of transport |
WGK Germany | WGK 1 |
Flash Point F | does not flash |
Flash Point C | does not flash |
Получите коммерческое предложение в течение 1 часа
Менеджер подготовит коммерческое предложение и позвонит, если понадобится уточнить детали вашего заказа

С 2010 года мы поставляем оборудование с заводов Европы. Берем на себя все — от подбора оборудования до внедрения на предприятии

Все сотрудники имеют высшее образование, закончили ведущие химические вузы страны, такие как РХТУ им Менделеева.

У большинства компаний срок ожидания составляет 10-12 недель.

Оборудование хранится на сухом отапливаемом складе, где поддерживается ровная температура.

Работаем с PonyExpress и Деловыми линиями. Вы также можете выбрать свою транспортную компанию или забрать товар со склада в Москве.

В случае любых неполадок за свой счет выполним ремонт в сервисном центре или на заводе-изготовителе. Или бесплатно заменим прибор на новый.

Производим пуско-наладку оборудования, валидацию, обучение сотрудников. Если нужно, привлекаем инженеров с заводов- изготовителей.