- Производитель:
- Roche
NACRES: | NA.55 |
Кат. номер |
KK5802 |
KK5801 |
KAPA2G Fast HotStart PCR Kits are designed for fast PCR, in which total reaction times are 20–70% shorter than those of conventional PCR assays performed with wild-type Taq DNA polymerase. This can be achieved without sacrificing reaction performance and does not require specialized PCR consumables or thermocyclers.
- Typing of transgenic organisms
- Amplification of microsatellites
- Typing and detection of pathogens
- Amplification of multiple DNA fragments for single nucleotide polymorphism (SNP) genotyping
- Semi-quantitative PCR
- 3-plex PCR
Biochem/physiol Actions
DNA fragments generated with KAPA2G Fast DNA Polymerase have the same characteristics as DNA fragments generated with wild-type Taq DNA polymerase, and may be used for sequencing, restriction enzyme digestion and cloning. Like wild-type Taq, KAPA2G Fast has 53 polymerase and 53 exonuclease activities, but no 35 exonuclease (proofreading) activity. The fidelity of KAPA2G Fast is similar to that of wild-type Taq; it has an error rate of approximately 1 error per 1.7 x 105 nucleotides incorporated. PCR products generated with KAPA2G Fast are 3-dA-tailed and may be cloned into TA cloning vectors.
Features and Benefits
Improve sensitivity, specificity, and yields
- Uniform representation of all amplicons
- Successful multiplex PCR with difficult, GC-rich targets
Increase speed without compromising performance
- 60% reduction in cycling time
- Extension times as low as 15 seconds
Quick Notes:
- KAPA2G Fast Multiplex Mix contains the engineered KAPA2G Fast HotStart DNA Polymerase, for fastand efficient multiplex PCR.
- The KAPA2G Fast Multiplex Mix contains a buffer optimized for multiplex PCR, with 0.2 mM of each dNTP and 3 mM MgCl2 (at 1X).
- Use 0.2 µM of each primer, and 10–100 ng of template DNA per reaction.
- Anneal at 60°C for 30 seconds.
- Perform extension for 15 sec, and increase for longer amplicons, and/or highly multiplexed reactions.
Quality
Each batch of KAPA2G Fast HotStart DNA Polymerase is confirmed to contain <2% contaminating protein (AgilentProtein 230 Assay). KAPA2G Fast Multiplex PCR Kits are subjected to stringent quality control tests, are free of contaminating exo- and endonuclease activity, and meet strict requirements with respect to DNA contaminationlevels.
Preparation Note
Always ensure that the product has been fully thawed and mixed before use. Reagents may be stored at 4°C for short-term use (up to 1 month). Return to -20°C for long-term storage. Provided that the ReadyMix has been handled carefully and not contaminated, the kit is not expected to be compromised if left (unintentionally) at room temperature for a short period of time (up to 3 days). Long-term storage at room temperature and 4°C is not recommended. Please note that reagents stored at temperatures above -20°C are more prone to degradation when contaminated during use, and therefore storage at such temperatures is at the users own risk.
shelf life | ≤12 mo. |
Quality Level | 100, |
packaging | kit of 1.25 mL (100 x 25 μL rxn; KK5801), kit of 6.25 mL (500 x 25 μL rxn; KK5802) |
Торговая марка | Roche |
concentration | 2 x |
application(s) | PCR: suitable |
shipped in | dry ice |
storage temp. | −20°C |
pictograms | GHS07,GHS08 |
signalword | Warning |
hcodes | H302 - H371 |
pcodes | P260 - P264 - P270 - P301 + P312 + P330 - P308 + P311 - P501 |
RIDADR | NONH for all modes of transport |
WGK Germany | WGK 1 |
Flash Point F | does not flash |
Flash Point C | does not flash |
Получите коммерческое предложение в течение 1 часа
Менеджер подготовит коммерческое предложение и позвонит, если понадобится уточнить детали вашего заказа

С 2010 года мы поставляем оборудование с заводов Европы. Берем на себя все — от подбора оборудования до внедрения на предприятии

Все сотрудники имеют высшее образование, закончили ведущие химические вузы страны, такие как РХТУ им Менделеева.

У большинства компаний срок ожидания составляет 10-12 недель.

Оборудование хранится на сухом отапливаемом складе, где поддерживается ровная температура.

Работаем с PonyExpress и Деловыми линиями. Вы также можете выбрать свою транспортную компанию или забрать товар со склада в Москве.

В случае любых неполадок за свой счет выполним ремонт в сервисном центре или на заводе-изготовителе. Или бесплатно заменим прибор на новый.

Производим пуско-наладку оборудования, валидацию, обучение сотрудников. Если нужно, привлекаем инженеров с заводов- изготовителей.