- Производитель:
- Roche
Capacity: The High Pure Spin Filter Tubes hold up to 700 µL sample volume.
Sample Material: Solid tissue (e.g., mouse liver, spleen, lung, heart): 1 - 25 mg.
Note: Sample size depends on the method used to prepare the tissue; larger samples (>10 mg) should be processed via rotor-stator homogenization.
- RT-PCR
- Northern blotting
- RACE
- Primer extension
- Differential display
- cDNA library construction
- RNase protection assay
- In vitro translation
Features and Benefits
- Prepare RNA samples in approximately 30 minutes.
- Obtain concentrated RNA that is suitable for downstream applications.
- Minimize RNA loss with a kit that removes contaminants without precipitation or other handling steps that degrade RNA.
- Eliminate the use of hazardous organic compounds such as cesium chloride, phenol, chloroform, and ethidium bromide.
Components
- Lysis/Binding Buffer
- DNase I, lyophilizate
- DNase Incubation Buffer
- Wash Buffer I
- Wash Buffer II
- Elution Buffer
- High Pure Spin Filter Tubes (containing glass fiber fleece)
- Collection Tubes
Quality
- Tissue is disrupted and homogenized in Lysis/Binding Buffer and purified as described.
- RNA yield is determined by measuring the optical density at 260 nm.
- Integrity and size distribution are examined by the banding pattern of ribosomal RNA in a denaturing agarose gel.
- 10 µL of the RNA eluate is used in first strand synthesis with reverse transcriptase M-MuLV and p(dT)15 as primer. In the following PCR, accomplished using the Expand High Fidelity PCR System and specific primers for glycerinaldehyde 3-phosphate dehydrogenase (GAPDH), the expected amplification product of 983 bp is obtained.
- Absence of contaminating DNA is examined by a PCR without a preceding RT reaction; no amplification product is obtained.
Preparation Note
Tissue samples are disrupted and homogenized in the presence of a chaotropic salt (guanidine HCL) that inactivates RNases. The homogenate is then applied to the glass fiber fleece in a High Pure Spin Filter Tube. Under the buffer conditions used in the procedure, all nucleic acids bind to the glass fiber fleece, while contaminating substances (salts, proteins, and other cellular contaminants) do not. DNA in the preparation is digested with DNase I directly on the filter. Brief wash-and-spin steps readily remove the digested DNA fragments and other cellular contaminants. The remaining purified RNA is then eluted in a small volume of low-salt buffer.
For life science research only. Not for use in diagnostic procedures.
Figure 1: Comparison of different homogenization procedures. Mouse liver was homogenized using various procedures. Total RNA was purified from each of these homogenates with the High Pure RNA Tissue Kit. Aliquots of the isolated RNA were reverse transcribed with primers specific for a region of the GADH mRNA. cDNA products were analyzed via gel electrophoresis.
Lane 1: Homogenization: Ultra Turrax; yield: 1.9 µg/mg tissue; A 260/ A 280 : 2.0
Lane 2: Homogenization: motor-driven, disposable plastic pestle; yield: 3 µg/mg tissue; A 260 /A 280 : 2.0
Lane 3: Homogenization: mortar and pestle, 20 G needle; yield: 1.5 µg/mg tissue; A 260 /A 280 : 2.0
Lane 4: Homogenization: manual disposable plastic pestle, 20 G needle; yield: 1.8 µg/mg tissue; A 260 /A 280 : 2.0
Lane 5: Homogenization: manual disposable plastic pestle; yield: 3.4 µg/mg tissue; A 260 /A 280 : 2.0
Lane 6: Homogenization: bead-vortex; yield: 3 µg/mg tissue; A 260 /A 280 : 2.0
Lane 7: Molecular weight marker
Quality Level | 100, |
Торговая марка | Roche |
packaging | kit of for 50 isolations |
pictograms | GHS07,GHS08 |
signalword | Danger |
hcodes | H302 + H332 - H315 - H317 - H319 - H334 |
pcodes | P261 - P264 - P280 - P284 - P304 + P340 + P312 - P342 + P311 |
RIDADR | NONH for all modes of transport |
WGK Germany | WGK 1 |
Flash Point F | does not flash |
Flash Point C | does not flash |
Получите коммерческое предложение в течение 1 часа
Менеджер подготовит коммерческое предложение и позвонит, если понадобится уточнить детали вашего заказа

С 2010 года мы поставляем оборудование с заводов Европы. Берем на себя все — от подбора оборудования до внедрения на предприятии

Все сотрудники имеют высшее образование, закончили ведущие химические вузы страны, такие как РХТУ им Менделеева.

У большинства компаний срок ожидания составляет 10-12 недель.

Оборудование хранится на сухом отапливаемом складе, где поддерживается ровная температура.

Работаем с PonyExpress и Деловыми линиями. Вы также можете выбрать свою транспортную компанию или забрать товар со склада в Москве.

В случае любых неполадок за свой счет выполним ремонт в сервисном центре или на заводе-изготовителе. Или бесплатно заменим прибор на новый.

Производим пуско-наладку оборудования, валидацию, обучение сотрудников. Если нужно, привлекаем инженеров с заводов- изготовителей.