Enzyme Commission (EC) Number: | 3.4.22.8 ( BRENDA | IUBMB ) |
Specificity
Endoproteinase Arg-C Sequencing Grade is a cysteine protease that specifically cleaves peptide, ester, and amide bonds at the C-terminal side of arginine residues. The specificity is primarily to arginine residues, although hydrolysis proceeds to a minor degree in most lysine-containing substrates. Reducing agents (such as DTT) and Ca2+ are required for full activity.
The specificity of Endoproteinase Arg-C Sequencing Grade is tested with the oxidized B-chain of insulin (insulin Box) as a substrate. High concentrations of Endoproteinase Arg-C Sequencing Grade are incubated for prolonged incubation times to detect traces of impurities such as contaminating proteases.
Recognition sites: C-terminal side of arginine residues, other recognition sites with lower efficiency.
Quality
Purity: Free of impurities that may interfere with the specific cleavage or separation of peptides in reversed-phase HPLC.
Preparation Note
Working concentration: Nutridoma-CS (50x) is diluted 1:50 (v/v) in basal medium. It is strongly suggested to use RPMI 1640. The final protein concentration is less than 1 mg/ml. The final medium should also contain L-glutamine and -mercaptoethanol.
Inhibitors: Oxidizing agents, sulfhydryl reactants (e.g., TLCK), EDTA, Co2+, Cu2+, Cd2+. Citrate, borate, and Tris anions partially inhibit.
Optimum pH: 7.2 - 8.0
Storage conditions (working solution): -15 to -25°C
For long-term use, the solution should be gently flushed with a stream of nitrogen and stored at -15 to -25°C. The reconstituted incubation buffer is stable for several months at -15 to -25°C.
Reconstitution
The lyophilized endoproteinase Arg-C sequencing grade is reconstituted in 50 µl double-dist. water to give a final concentration of 50 mM Tris-HCl buffer, 10 mM CaCl2, 5 mM EDTA, pH 8.0. The lyophilized activation solution is dissolved in 100 µl double-dist. water resulting in a final 50 mM dithiothreitol-(DTT-)concentration and 5 mM EDTA-concentration.
form | lyophilized |
mol wt | Mr 59 kDa |
packaging | pkg of 3 x 5 µg |
Торговая марка | Roche |
parameter | 37 °C optimum reaction temp. |
optimum pH | 7.2-8.0 |
shipped in | wet ice |
storage temp. | 2-8°C |
pictograms | GHS05,GHS07,GHS08 |
signalword | Danger |
hcodes | H302 - H315 - H318 - H334 |
pcodes | P261 - P264 - P280 - P304 + P340 - P305 + P351 + P338 + P310 - P342 + P311 |
RIDADR | NONH for all modes of transport |
WGK Germany | WGK 2 |
Flash Point F | does not flash |
Flash Point C | does not flash |
Получите коммерческое предложение в течение 1 часа
Менеджер подготовит коммерческое предложение и позвонит, если понадобится уточнить детали вашего заказа

С 2010 года мы поставляем оборудование с заводов Европы. Берем на себя все — от подбора оборудования до внедрения на предприятии

Все сотрудники имеют высшее образование, закончили ведущие химические вузы страны, такие как РХТУ им Менделеева.

У большинства компаний срок ожидания составляет 10-12 недель.

Оборудование хранится на сухом отапливаемом складе, где поддерживается ровная температура.

Работаем с PonyExpress и Деловыми линиями. Вы также можете выбрать свою транспортную компанию или забрать товар со склада в Москве.

В случае любых неполадок за свой счет выполним ремонт в сервисном центре или на заводе-изготовителе. Или бесплатно заменим прибор на новый.

Производим пуско-наладку оборудования, валидацию, обучение сотрудников. Если нужно, привлекаем инженеров с заводов- изготовителей.