The enzyme is an isoschizomer to Bsp143 I, Dpn II, Mbo I, Nde II and Sau3A I.
Methylation sensitivity
The enzyme is only inhibited by the occurrence of 5-methylcytosine at the indicated site (*) if no 6-methyladenine is present.
Typical ligation and recutting assay
Dpn I fragments obtained by complete digestion of 1µg pBR322 DNA are ligated for 16 hours at +4°C with 1U T4 DNA Ligase in 10µl buffer that contains 66mM Tris-HCl, 5mM MgCl2, 5mM Dithiothreitol, 1mM ATP, pH 7.5 (at +20°C). The percentages of product that can be ligated and subsequently recut with Dpn I (yielding the typical pattern of pBR322 x Dpn I fragments) are stated under "Lig" and "Rec" in the certificate of analysis.
Dpn I requires methylation of adenine residues for activity and thus digests only GmATC sequences containing N6-methyladenine. Such methylated sequences are produced by dam methylase. This requirement for methylation distinguishes Dpn I from Mbo I, which is inhibited by dam methylation, and Sau3A I, which is not influenced by dam methylation. Dpn I also cleaves at a different position on the recognition sequence than Mbo I and Sau3A I.
Specificity
Recognition sites: GmAT*C
GmAT*C
Restriction site: GmAT*C
GmAT*C
Heat inactivation: No inactivation of Dpn I after incubation at 65 °C for 15 minutes.
Quality
Absence of nonspecific endonuclease activities
1µg pBR322 DNA is incubated for 16 hours in 50µl SuRE/Cut Buffer A with an excess of Dpn I. The number of enzyme units which do not change the enzyme-specific pattern is stated in the certificate of analysis.
Absence of exonuclease activity
Approximately 5µg [3H] labeled calf thymus DNA are incubated with 3µl Dpn I for 4 hours at +37°C in a total volume of 100µl 50mM Tris-HCl, 10mM MgCl2, 1mM Dithioerythritol, pH approximately 7.5. Under these conditions, no release of radioactivity is detectable, as stated in the certificate of analysis.
Compatibility
Dpn I generates fragments with blunt ends that are compatible with any blunt end.
DNA Profile
Number of cleavage sites on different DNAs
- : 116
- X174: 0
- Ad2: 87
- M13mp7: 8
- pBR322: 22
- pBR328: 27
- pUC18: 15
- SV40: 8
Unit Definition
One unit is the enzyme activity that cleaves 1 µg pBR322 DNA in one hour at +37 °C in a total volume of 25 µl (1x) SuRE/Cut Buffer A. Since complete Dpn I digestion of pBR322 DNA needs fully methylated GATC sequences < 5% partial digested bands may be observed during activity determination.
Analysis Note
Activity in PCR buffer: 100%
Relative activity in PCR mix (Taq DNA Polymerase buffer) is 100%. The PCR mix contained DNA, primers, 10 mM Tris-HCl (pH 8.3, 20 °C), 50 mM KCl, 1.5 mM MgCl2, 200 µM dNTPs, 2.5 U Taq DNA polymerase. The mix was subjected to 25 amplification cycles.Activity in reaction buffer of Pwo SuperYield DNA Polymerase PCR Mix is 100%; Pwo SuperYield DNA Polymerase PCR Mix is not available in U.S.
SuRE/Cut Buffer System
The buffer in bold is recommended for optimal activity
- A: 100%
- B: 75-100%
- H: 75-100%
- L: 50-75%
- M: 75-100%
Quality Level | 100, |
form | solution |
packaging | pkg of 1,000 U (10742988001 [10 U/µl]), pkg of 200 U (10742970001 [10 U/µl]) |
Торговая марка | Roche |
parameter | 37 °C optimum reaction temp. |
shipped in | dry ice |
storage temp. | 20°C |
RIDADR | NONH for all modes of transport |
Получите коммерческое предложение в течение 1 часа
Менеджер подготовит коммерческое предложение и позвонит, если понадобится уточнить детали вашего заказа

С 2010 года мы поставляем оборудование с заводов Европы. Берем на себя все — от подбора оборудования до внедрения на предприятии

Все сотрудники имеют высшее образование, закончили ведущие химические вузы страны, такие как РХТУ им Менделеева.

У большинства компаний срок ожидания составляет 10-12 недель.

Оборудование хранится на сухом отапливаемом складе, где поддерживается ровная температура.

Работаем с PonyExpress и Деловыми линиями. Вы также можете выбрать свою транспортную компанию или забрать товар со склада в Москве.

В случае любых неполадок за свой счет выполним ремонт в сервисном центре или на заводе-изготовителе. Или бесплатно заменим прибор на новый.

Производим пуско-наладку оборудования, валидацию, обучение сотрудников. Если нужно, привлекаем инженеров с заводов- изготовителей.