4744934001 |
4744926001 |
- The Cytotoxicity Detection KitPLUS (LDH) is a fast, sensitive, and simple method to quantify cytotoxicity/cytolysis based on the measurement of LDH activity released from damaged cells using the 96-well or 384-well plate format. The kit can be used in many different in vitro cell systems when damage to the plasma membrane occurs. For example: Detection and quantification of cell-mediated cytotoxicity.
- Determination of mediator-induced cytolysis.
- Determination of the cytotoxic potential of compounds in environmental and medical research, and in the food, cosmetic, and pharmaceutical industries.
- Determination of cell death in bioreactors.
Features and Benefits
- Flexible, since the assay can determine the degree of plasma membrane damage in many different in vitro cell systems.
- Safe, because the assay does not use radioactive isotopes.
- Accurate, since assay results strongly correlate to the number of lysed cells.
- Sensitive, since the assay can detect even low cell numbers.
- Fast, since assay results can be determined on a multi-well ELISA reader, which allows simultaneous processing of many samples.
- Convenient, since the assay does not require a prelabeling step.
Packaging
- 04744926001 (1 kit containing 4 components)
- 04744934001 (1 kit containing 4 components)
1 kit containing 4 components
Preparation Note
Working solution: Catalyst:
Dissolve the lyophilizate in 1 ml double dist. water for 10 min, then mix thoroughly.
Reaction mixture:
For 100 tests: Shortly before use, mix 250 µl of reconstituted catalyst with 11.25 ml dye solution
For 400 tests: Shortly before use, add the total volume of reconstituted catalyst (1 ml) to the total volume of dye solution (45 ml) and mix well.
Note: In case you observe crystals in “Dye solution”, shake the bottle at least 1 hour at 37 °C. Remaining precipitates will NOT influence the performance.
Note: The precipitates were formed during the freezing of the product. Repeated freezing and thawing should be avoided.
Note: Prepare immediately before use. Do not store the Reaction mixture.
Storage conditions (working solution): The lyophilizate is stable at 2 to 8 °C.
The reconstituted catalyst solution, the dye solution the lysis solution and the stop solution are stable for
- Four weeks when stored at 2 to 8 °C
- Two days at 15 to 25 °C
- For long-term storage (up to 3 months), store bottles at -15 to -25 °C.
- Freezing and thawing the solutions up to three times will not significantly reduce their performance. When crystals are seen in Dye solution, shake the bottle at least one hour at 37 °C. Remaining precipitates will not influence performance. As the precipitates can be formed during freezing of the product, repeated freezing and thawing should be avoided.
form | liquid |
Quality Level | 100, |
usage | sufficient for 2,000 multiwell tests (04744934001), sufficient for 400 multiwell tests (04744926001) |
Торговая марка | Roche |
storage condition | avoid repeated freeze/thaw cycles |
application(s) | cell analysis: suitable, detection: suitable, protein quantification: suitable |
max | 490-492 nm |
detection method | colorimetric |
shipped in | dry ice |
storage temp. | 20°C |
RIDADR | UN 1789 8 / PGIII |
Получите коммерческое предложение в течение 1 часа
Менеджер подготовит коммерческое предложение и позвонит, если понадобится уточнить детали вашего заказа

С 2010 года мы поставляем оборудование с заводов Европы. Берем на себя все — от подбора оборудования до внедрения на предприятии

Все сотрудники имеют высшее образование, закончили ведущие химические вузы страны, такие как РХТУ им Менделеева.

У большинства компаний срок ожидания составляет 10-12 недель.

Оборудование хранится на сухом отапливаемом складе, где поддерживается ровная температура.

Работаем с PonyExpress и Деловыми линиями. Вы также можете выбрать свою транспортную компанию или забрать товар со склада в Москве.

В случае любых неполадок за свой счет выполним ремонт в сервисном центре или на заводе-изготовителе. Или бесплатно заменим прибор на новый.

Производим пуско-наладку оборудования, валидацию, обучение сотрудников. Если нужно, привлекаем инженеров с заводов- изготовителей.