- HiTrap columns prepacked with Ni Sepharose excel medium, resistant to chelating and reducing agents
- Load eukaryotic cell culture samples containing secreted histidine-tagged proteins directly with retained binding capacity
- Increase target protein yield and decrease degradation through reduced and simplified sample handling
- HisTrap excel columns allow direct purification of cell-free, unclarified samples.
HisTrap is a trademark of Cytiva
shelf life | Please be aware this product may be shipped 90 days before the expiration date. For more information on the batch specific expiration date, please contact technical service. |
packaging | pack of 1 mL |
Торговая марка | Cytiva |
availability | not available in North America |
parameter | 1 ml/min - 4 ml/min flow rate (H2O at room temperature. Maximum flow rate will be lower when using buffers or samples with high viscosity or performing purification at low temperature. Optimal flow rate during binding is sample-dependent. During column wash and elution, a flow rate of 1 ml/min is recommended.), 5 bar |
bed size | 7 mm x 25 mm |
bed volume | 1 mL |
column I.D. | 7 mm |
matrix | highly cross-linked 6% agarose |
average diameter | 90 µm |
cleaning | 2 - 14 (Cleaning-in-place: pH interval where the medium can be subjected to cleaning-in-place without significant change in function.) |
working range | 2 - 13 |
capacity | 10 mg binding capacity (histidine-tagged protein)(H2O at room temperature. Maximum flow rate will be lower when using buffers or samples with high viscosity or performing purification at low temperature. Optimal flow rate during binding is sample-dependent. During column wash and elution, a flow rate of 1 ml/min is recommended.), 10 mg binding capacity (histidine-tagged protein/ml sedimented medium)(Dynamic binding capacity was tested with 0.5 mg/ml (histidine)6 tagged pure protein (Mr 43 000) in EX-CELL® 420 Insect serum-free medium (capacity at 10% breakthrough) or (histidine)6-tagged protein (Mr 28 000). Column volume was 1 ml and flow rate 1 ml/min. Binding capacity is sample-dependent.) |
signalword | Warning |
hcodes | H226 |
pcodes | P210-P235-P241-P280-P303 + P361 + P353-P501 |
RIDADR | NA 1993 / PGIII |
Получите коммерческое предложение в течение 1 часа
Менеджер подготовит коммерческое предложение и позвонит, если понадобится уточнить детали вашего заказа

С 2010 года мы поставляем оборудование с заводов Европы. Берем на себя все — от подбора оборудования до внедрения на предприятии

Все сотрудники имеют высшее образование, закончили ведущие химические вузы страны, такие как РХТУ им Менделеева.

У большинства компаний срок ожидания составляет 10-12 недель.

Оборудование хранится на сухом отапливаемом складе, где поддерживается ровная температура.

Работаем с PonyExpress и Деловыми линиями. Вы также можете выбрать свою транспортную компанию или забрать товар со склада в Москве.

В случае любых неполадок за свой счет выполним ремонт в сервисном центре или на заводе-изготовителе. Или бесплатно заменим прибор на новый.

Производим пуско-наладку оборудования, валидацию, обучение сотрудников. Если нужно, привлекаем инженеров с заводов- изготовителей.