453,00 / 43 330
Получить предложение

Производитель может поднять цены — запросите коммерческое предложение сейчас, и мы зафиксируем за вами текущую цену.

  • img
    Привезем под заказ
  • img
    Срок поставки с завода 6-8 недель

ATM/Chk2 Pathway Explorer Antibody MiniPack 15-116

Гарантия 1 год
Код:
15-116
Производитель:
Sigma-Aldrich
Онлайн консультант Анна Головацкая
Онлайн консультант Анна Головацкая Получить консультацию эксперта
Производитель:
Sigma-Aldrich
eCl@ss:32160702
NACRES:NA.41

General description
Pathway Explorer Antibody MiniPack:
Each Pathway Explorer Antibody Minipack contains three related antibodies as part of a signaling cascade or a combination of total and phosphorylated forms of key signaling targets. Each of the three antibodies are 30% the original pack size. Full size versions of each of the Pathway Explorer antibodies are available for sale individually under the same catalog number with the removal of “SP” off of each one (e.g. 05-591SP can be ordered as 05-591).
ATM:
Ataxia telangiectasia mutated kinase (ATM) and ataxia telangiectasia and Rad3-related kinase (ATR) are related kinases that regulate cell cycle checkpoints and DNA repair. Mutation in the ATM gene results in the autosomal recessive disease ataxia telangiectasia (AT). The identified substrates for ATM are p53, p95/NBS1, MDM2, Chk2, BRCA1, CtIP, 4E-BP1 and Chk1. The essential requirement for the substrates of ATM/ATR is S/TQ. Hydrophobic amino acids at positions -3 and -1, and negatively charged amino acids at position +1 are positive determinants for substrate recognition by these kinases. Positively charged residues surrounding the S/TQ are negative determinants for substrate phosphorylation. The complex phenotype of cells derived from patients with AT suggests that ATM has additional cellular substrates. In unirradiated cells, ATM is present as an inactive homodimer or multimer. Double-stranded breaks in DNA caused by ionizing radiation cause rapid ATM kinase activation through dissociation of this complex and ATM autophosphorylation at Ser1981.
Chk2:
The p53 tumor-suppressor gene integrates numerous signals that control cell life and death. Several novel molecules involved in p53 signaling, including Chk2, p53R2, p53AIP1, Noxa, PIDD, and PID/MTA2, were recently discovered. The checkpoint kinase Chk2 is the mammalian homologue of yeast Cds1/Rad53. In response to DNA damage, the checkpoint kinase ATM phosphorylates and activates Chk2, which in turn directly phosphorylates and activates p53. Chk2 serves as ATM downstream effector to mediate activation of p53. Chk2 also phosphorylates and activates BRCA1, the product of a tumor suppressor gene that is mutated in breast and ovarian cancer.
* See full size versions for corresponding references.
Specificity
05-649SP and 05-740SP: Others not tested.
05-513SP: Other species not tested.
05-649SP and 05-740SP: Predicted to cross-react with rat based on sequence homology.
Immunogen
05-649SP: Mixture of two GST fusion proteins corresponding to residues 1-223 and 217-543 of human Chk2;05-740SP: KLH-conjugated, synthetic peptide corresponding to amino acids 1974-1988 (SLAFEEG[pS]QSTTISS) of human ATM. The immunizing sequence has 11/12 identical amino acids in mouse and rat.;05-513SP: Full length human ATM. Clone AM9.
Epitope: 05-740SP:Ser1981
Application
This Antibody pack contains Anti-ATM Antibody, Anti-phospho-ATM Antibody (Ser1981), Anti-Chk2 Antibody validated for use in WB, ICC & IP.
Research Sub Category
Cell Cycle, DNA Replication & Repair
Research Category
Signaling
Packaging
Each vial is 30% the size of the parent catalog number
Components
05-513SP Anti-ATM, clone AM9
05-740SP Anti-phospho-ATM (Ser1981),
clone 10H11.E12
05-649SP Anti-Chk2, clone 7
Quality
05-649SP: Routinely evaluated by immunoblot on RIPA lysates from Jurkat cells, HeLa, 3T3/A31, or A431 cells.
Western Blot Analysis: 0.1-1 µg/mL of this lot detected Chk2 in RIPA lysates from Jurkat cells. A previous lot detected Chk2 in lysates from HeLa, 3T3/A31, and A431 cells.
05-740SP: Routinely evaluated by immunoblot on in crude lysates from irradiated HeLa cells.
Western Blot Analysis: 0.5 µg/mL of this lot detected phosphorylated ATM in crude lysates from irradiated HeLa cells.
05-513SP: Routinely evaluated by immunoblot on nuclear extract from Raji cells.
Western Blot Analysis:
1:250-1:1000 dilution of this lot detected ATM in a nuclear extract from Raji cells.
Target description
05-649SP: 67 kDa;05-740SP:~370 kDa;05-513SP: 350 kDa
Physical form
3 individual tubes containing either Anti-ATM, clone AM9; Anti-phospho-ATM (Ser1981), clone 10H11.E12; or Anti-Chk2, clone 7
Storage and Stability
Stable for 1 year at -20°C from date of receipt.
For maximum recovery of product, centrifuge the vial prior to removing the cap.
Analysis Note
Control
For 05-649SP use Jurkat cell lysate, HeLa cell lysate.
For 05-740SP use Irradiated HeLa cell lysates.
For 05-513SP use Raji cells
Other Notes
Concentration: Please refer to the Certificate of Analysis for the lot-specific concentration.
Legal Information
UPSTATE is a registered trademark of Merck KGaA, Darmstadt, Germany
Disclaimer
Unless otherwise stated in our catalog or other company documentation accompanying the product(s), our products are intended for research use only and are not to be used for any other purpose, which includes but is not limited to, unauthorized commercial uses, in vitro diagnostic uses, ex vivo or in vivo therapeutic uses or any type of consumption or application to humans or animals.
Параметры
Quality Level100
biological sourcemouse
antibody product typeprimary antibodies
clone10H11.E12, monoclonal","7, monoclonal","AM9, monoclonal
species reactivityhuman (05-513SP,05-649SP, 05-740SP), mouse (05-649SP and 05-740SP), rat
Торговая маркаUpstate®
application(s)immunocytochemistry: suitable","immunoprecipitation (IP): suitable","thin layer chromatography (TLC): suitable","western blot: suitable
conjugateunconjugated
NCBI accession no.NP_000042,","NP_001005735,
UniProt accession no.O96017,
shipped inwet ice
Пуско-наладка
Выполним распаковку, визуальную проверку, сборку и установку, запуск и настройку, проверку функциональности, проведем инструктаж персонала.
Техническое обслуживание
Проведем периодические регламентные работы: визуальный осмотр, очистка засоренных узлов и частей, замена расходных материалов и изношенных деталей, тестирование прибора, проверка показателей и измерение параметров, калибровка и настройка, обновление программного обеспечения.
IQ/OQ/PQ квалификация, валидация
Проведем монтажную (IQ), операционную (OQ) и эксплуатационную (PQ) квалификацию оборудования по протоколам производителя в полном соответствии с стандартами GMP/GLP.
Ремонт
Проведем диагностику в нашем сервисном центре или у Вас на предприятии, выявим причину поломки, устраним неисправность, проведем тестирование, настройку, калибровку отремонтированного оборудования.

Получите коммерческое предложение в течение 1 часа

Менеджер подготовит коммерческое предложение и позвонит, если понадобится уточнить детали вашего заказа

img
Анна Гловацкая Менеджер по работе с клиентами
Получите коммерческое предложение в течение 1 часа
Как к вам обращаться?
Введите телефон
Введите email
Комментарий (если есть)
Прикрепить ТЗ или заявку (до 10 мб)

С 2010 года мы поставляем оборудование с заводов Европы. Берем на себя все — от подбора оборудования до внедрения на предприятии

img
Обрудование подберут сотрудники с высшим химическим образованием

Все сотрудники имеют высшее образование, закончили ведущие химические вузы страны, такие как РХТУ им Менделеева.

img
Организуем поставку с завода- изготовителя за 6-8 недель

У большинства компаний срок ожидания составляет 10-12 недель.

img
Храним оборудование по требованиям производителя

Оборудование хранится на сухом отапливаемом складе, где поддерживается ровная температура.

img
Доставим по Москве на следующий день, по России — за 3-4 дня

Работаем с PonyExpress и Деловыми линиями. Вы также можете выбрать свою транспортную компанию или забрать товар со склада в Москве.

img
Выполним бесплатный ремонт и сервисное обслуживание

В случае любых неполадок за свой счет выполним ремонт в сервисном центре или на заводе-изготовителе. Или бесплатно заменим прибор на новый.

img
Обеспечим легкое внедрение на предприятие

Производим пуско-наладку оборудования, валидацию, обучение сотрудников. Если нужно, привлекаем инженеров с заводов- изготовителей.

Отзывы

453,00 / 43 330
Получить предложение

Производитель может поднять цены — запросите коммерческое предложение сейчас, и мы зафиксируем за вами текущую цену.

  • img
    Привезем под заказ
  • img
    Срок поставки с завода 6-8 недель

ATM/Chk2 Pathway Explorer Antibody MiniPack 15-116

Гарантия 1 год
Код:
15-116
Производитель:
Sigma-Aldrich
Онлайн консультант Анна Головацкая
Онлайн консультант Анна Головацкая Получить консультацию эксперта

Похожие товары: