- Производитель:
- Millipore
The SMC™ Human IFN-2 High Sensitivity Immunoassay Kit contains all reagents required to perform the assay. This assay takes advantage of a standard immunoassay workflow configured in a standard plate format.
Assay protocols are similar to existing sandwich ELISA methods with two key differences:
1) Elution buffer disrupts the sandwich, separating the labeled detection antibody for quantification.
2) The Erenna and SMCxPRO™ immunoassay systems detect analytes using Single Molecule Counting (SMC™) technology.
This assay was tested for cross reactivity with rhIFN-, rhIFN-, rhIFN-1 (IL-29), rhIFN-2 (IL28A), rhIFN-3 (IL-28B), rhIFN-, IFN-2a, IFN-2b and IFN-.
- There is no cross-reactivity detected with rhIFN-, rhIFN-, rhIFN-1 (IL-29), rhIFN-2 (IL-28A),rhIFN-3 (IL-28B), and rhIFN-.
- There is 100% cross-reactivity with IFN-2a.
- There is 49% cross-reactivity with IFN-2b.
- There is 3% cross-reactivity with IFN-.
Accuracy:
- Minimum of 5 serum samples spiked with average recovery of 102% with a range of 92-111%
- Minimum of 5 plasma samples spiked with average recovery of 96% with a range of 89-107%
- Inflammation & Immunology
Research Sub-Category:
- Inflammatory Disease
- Immune Response
- Autoimmune disease
The sensitivity of the Single Molecule Counting (SMC™) technology gives the SMC™ Human IFN-a2 High Sensitivity Immunoassay Kit unparalleled performance in the quantification of IFN-a2 in human serum and plasma.
- Improved options for sample prep and incubation
- Lyophilization of the standard provides the kit at one storage condition
- Removal of a plate transfer step
- Increased reagent volumes to accommodate automation
- Validated to run on both SMCxPRO™ and Erenna
- Assay Buffer
- IFN-a2 Coated Beads
- Standard Diluent
- IFN-a2 Detection Antibody
- IFN-a2 Standard
- 10X Wash Buffer
- Buffer D
- Elution Buffer B
SMCxPRO is a trademark of Merck KGaA, Darmstadt, Germany
Unless otherwise stated in our catalog or other company documentation accompanying the product(s), our products are intended for research use only and are not to be used for any other purpose, which includes but is not limited to, unauthorized commercial uses, in vitro diagnostic uses, ex vivo or in vivo therapeutic uses or any type of consumption or application to humans or animals.
species reactivity | feline, canine, nonhuman primates, rat, porcine |
Торговая марка | SMC™ |
assay range | sensitivity: 0.062 pg/mL (lower limit of quantification), inter-assay cv: <13% intra-assay cv: <9% (studied using five normal plasma samples run in triplicate by 3 different operators on 3 different days.) |
application(s) | ELISA: suitable, single molecule counting: suitable |
relevant disease(s) | autoimmune diseases |
storage temp. | 2-8°C |
Получите коммерческое предложение в течение 1 часа
Менеджер подготовит коммерческое предложение и позвонит, если понадобится уточнить детали вашего заказа

С 2010 года мы поставляем оборудование с заводов Европы. Берем на себя все — от подбора оборудования до внедрения на предприятии

Все сотрудники имеют высшее образование, закончили ведущие химические вузы страны, такие как РХТУ им Менделеева.

У большинства компаний срок ожидания составляет 10-12 недель.

Оборудование хранится на сухом отапливаемом складе, где поддерживается ровная температура.

Работаем с PonyExpress и Деловыми линиями. Вы также можете выбрать свою транспортную компанию или забрать товар со склада в Москве.

В случае любых неполадок за свой счет выполним ремонт в сервисном центре или на заводе-изготовителе. Или бесплатно заменим прибор на новый.

Производим пуско-наладку оборудования, валидацию, обучение сотрудников. Если нужно, привлекаем инженеров с заводов- изготовителей.