General description
Systemic lupus erythematosus (SLE) is a chronic autoimmune disease with a wide range of clinical manifestations and the presence of multiple autoantibodies. Anti-Smith antibodies are highly specific for SLE and are reported to be of importance in the classification of this disease. Smith antigens (Sm) are RNase resistant, non-histone nuclear proteins that are composed of several polypeptides of differing molecular weights. They include B, B , D1, D2, D3, E, F, and G polypeptides and associate with small ribonucleoproteins U1, U2, U4, U5, and U6. They are reported to be essential for the splicing of pre-mRNA in eukaryotes. Of these D1 and D3 are the most common antigens recognized by anti-Sm antibodies found in SLE subjects. Although Sm proteins are antigenically conserved and exist as RNA-protein complex, RNA does not play a major role in its antigenicity. Clone Y12 is reported to strongly react with native D1, D3, and B in immunoblot applications, but not with recombinantly expressed D1. It requires symmetrical dimethylarginines (sDMAs) for antigen recognition. This clone is reported to recognize an linear epitope (aa 95-119) in human D1 protein. (Ref.: Brahms, H., et al. (2000). J. Biol. Chem. 275(22); 17122-17129; Pettersson, I., et al. (1984). J. Biol. Chem. 259(9); 5907-5914; Dang, H., et al. (1983). J. Immunol 130(6); 2782-2785).
Specificity
Clone Y12 is a mouse monoclonal antibody that detects Smith Antigen.
Immunogen
Human Smith antigen.
Application
Quality Control Testing
Evaluated by Western Blotting in HCT116 cell lysate.
Western Blotting Analysis: A 1:500 dilution of this antibody detected Smith Antigen in HCT116 cell lysate.
Tested Applications
Western Blotting Analysis: A 1:500 dilution from a representative lot detected Smith Antigen in Caco-2 cell lysate.
Immunocytochemistry Analysis: A representative lot detected Smith Antigen in Immunocytochemistry (dos Santos, N.R. et al. (1997). Hum Mol Genet. 6(9): 1549-58).
Western Blotting Analysis: A representative lot detected Smith Antigen in Western Blotting applications (Naro, C. et al. (2019). Cell Rep. 26(11): 2929-2941; Somarelli, J.A., et al. (2011). Lupus. 20(3): 274-89; Brahms, H. et al. (2000). J Biol Chem. 275(22): 17122-9).
RNA Binding Protein Immunoprecipitation (RIP): A representative lot detected Smith Antigen in RNA Binding Protein Immunoprecipitation applications (Naro, C. et al. (2019). Cell Rep. 26(11):2929-2941).
Immunohistochemistry (Paraffin) Analysis: A 1:250 dilution from a representative lot detected Smith Antigen in human tonsil tissue sections.
ELISA Analysis: A representative lot detected Smith Antigen in ELISA applications (Zhou, Y, et al. (2017). J Immunol. 198(5):1846-1854).
Immunohistochemistry Applications: A representative lot detected Smith Antigen in Immunohistochemistry applications (Mirra, A., et al. (2017). Sci Rep. 7(1):2033).
Immunoprecipitation Analysis: A representative lot immunoprecipitated Smith Antigen in Immunoprecipitation applications (Learner, E.A., et al. (1981). Proc Natl Acad Sci USA. 78(5):2737-41; Naro, C. et al. (2019). Cell Rep. 26(11): 2929-2941; Mirra, A., et al. (2017). Sci Rep.;7(1): 2033; Fischer, U. et al. (1997). Cell. 90(6):1023-9).
Radioimmunoassay: A representative lot detected Smith Antigen in Radioimmunoassay applications (Learner, E.A., et al. (1981). Proc Natl Acad Sci USA.;78(5):2737-41).
Immunofluorescence Analysis: A representative lot detected Smith Antigen in Immunofluorescence applications (Learner, E.A., et al. (1981). Proc Natl Acad Sci USA.78(5):2737-41; Mirra, A., et al. (2017). Sci Rep. 7(1):2033).
Note: Actual optimal working dilutions must be determined by end user as specimens, and experimental conditions may vary with the end user
Anti-Smith Antigen, clone Y12, Cat. No. MABF2793, a mouse monoclonal antibody detects Smith antigen and is tested in ELISA, Immunohistochemistry, Immunofluorescence, Immunoprecipitation, RIA, RNA Binding Protein IP (RIP), and Western Blotting.
Physical form
Purified mouse monoclonal antibody IgG3 in buffer containing 0.1 M Tris-Glycine (pH 7.4), 150 mM NaCl with 0.05% sodium azide.
Storage and Stability
Recommend storage at +2°C to +8°C. For long term storage antibodies can be kept at -20°C. Avoid repeated freeze-thaws.
Other Notes
Concentration: Please refer to the Certificate of Analysis for the lot-specific concentration.
Disclaimer
Unless otherwise stated in our catalog or other company documentation accompanying the product(s), our products are intended for research use only and are not to be used for any other purpose, which includes but is not limited to, unauthorized commercial uses, in vitro diagnostic uses, ex vivo or in vivo therapeutic uses or any type of consumption or application to humans or animals.
Параметры
Quality Level200
biological sourcemouse
antibody formpurified antibody
antibody product typeprimary antibodies
cloneY12, monoclonal
mol wtcalculated mol wt 25 kDa","observed mol wt ~25 kDa
purified byusing protein G
species reactivitymouse, human
packagingantibody small pack of 100 µL
application(s)immunohistochemistry (formalin-fixed, paraffin-embedded sections): suitable","immunoprecipitation (IP): suitable","western blot: suitable
isotypeIgG3
conjugateunconjugated
UniProt accession no.N/A,
shipped in2-8°C

Safety Information
WGK GermanyWGK 1
Flash Point FNot applicable
Flash Point CNot applicable
Пуско-наладка
Выполним распаковку, визуальную проверку, сборку и установку, запуск и настройку, проверку функциональности, проведем инструктаж персонала.
Техническое обслуживание
Проведем периодические регламентные работы: визуальный осмотр, очистка засоренных узлов и частей, замена расходных материалов и изношенных деталей, тестирование прибора, проверка показателей и измерение параметров, калибровка и настройка, обновление программного обеспечения.
IQ/OQ/PQ квалификация, валидация
Проведем монтажную (IQ), операционную (OQ) и эксплуатационную (PQ) квалификацию оборудования по протоколам производителя в полном соответствии с стандартами GMP/GLP.
Ремонт
Проведем диагностику в нашем сервисном центре или у Вас на предприятии, выявим причину поломки, устраним неисправность, проведем тестирование, настройку, калибровку отремонтированного оборудования.

Получите коммерческое предложение в течение 1 часа

Менеджер подготовит коммерческое предложение и позвонит, если понадобится уточнить детали вашего заказа

img
Анна Гловацкая Менеджер по работе с клиентами
Получите коммерческое предложение в течение 1 часа
Как к вам обращаться?
Введите телефон
Введите email
Комментарий (если есть)
Прикрепить ТЗ или заявку (до 10 мб)

С 2010 года мы поставляем оборудование с заводов Европы. Берем на себя все — от подбора оборудования до внедрения на предприятии

img
Обрудование подберут сотрудники с высшим химическим образованием

Все сотрудники имеют высшее образование, закончили ведущие химические вузы страны, такие как РХТУ им Менделеева.

img
Организуем поставку с завода- изготовителя за 6-8 недель

У большинства компаний срок ожидания составляет 10-12 недель.

img
Храним оборудование по требованиям производителя

Оборудование хранится на сухом отапливаемом складе, где поддерживается ровная температура.

img
Доставим по Москве на следующий день, по России — за 3-4 дня

Работаем с PonyExpress и Деловыми линиями. Вы также можете выбрать свою транспортную компанию или забрать товар со склада в Москве.

img
Выполним бесплатный ремонт и сервисное обслуживание

В случае любых неполадок за свой счет выполним ремонт в сервисном центре или на заводе-изготовителе. Или бесплатно заменим прибор на новый.

img
Обеспечим легкое внедрение на предприятие

Производим пуско-наладку оборудования, валидацию, обучение сотрудников. Если нужно, привлекаем инженеров с заводов- изготовителей.

Отзывы

Узнать цену

Производитель может поднять цены — запросите коммерческое предложение сейчас, и мы зафиксируем за вами текущую цену.

  • img
    Привезем под заказ
  • img
    Срок поставки с завода 6-8 недель

Anti-Smith Antigen Antibody, clone Y12

Гарантия 1 год
Производитель:
Sigma-Aldrich
Онлайн консультант Анна Головацкая
Онлайн консультант Анна Головацкая Получить консультацию эксперта

Похожие товары: