- Производитель:
- Sigma-Aldrich
eCl@ss: | 32160702 |
NACRES: | NA.41 |
Кат. номер |
MABF1032 |
MABF1032-25UL |
Specificity
Clone 1D11 detects NKG2-D type II integral membrane protein in human cells.
Flow Cytometry Analysis: A 1:500 dilution from a representative lot detected NKG2D (CD314) in CD3-/CD56+ T cells (Courtesy of Alejandro Lopez-Soto, Ph.D., Tumor Immunology Group, Universidad de Oviedo, IUOPA Spain).
Inhibits Activity/Function: A representative lot of Anti-NKG2D (CD314), clone 1D11, reduced the percentage of degranulating NK cells in freshly isolated PBMCs when co-incubated with K562 cells (Courtesy of Alejandro Lopez-Soto, Ph.D., Tumor Immunology Group, Universidad de Oviedo, IUOPA Spain).
Immunohistochemistry Analysis: A representative lot detected NKG2D (CD314) in Immunohistochemistry applications (Groh, V., et. al. (2003). Proc Natl Acad Sci U S A. 100(16):9452-7).
Inhibition Analysis: A representative lot inhibited NKG2D activated cytolytic responses of gamma delta T cells and NK cells against transfectants and epithelial tumor cells expressing MICA. (Bauer, S., et. al. (1999). Science. 285(5428):727-9).
Stimulates ECM Adhesion: A representative lot of Anti-NKG2D (CD314), clone 1D11 stimulated ECM Adhesion (Abeyweera, T.P., et. al. (2011). J Cell Biol. 192(4):675-90).
Flow Cytometry Analysis: A representative lot detected NKG2D (CD314) in Flow Cytometry applications (Wu, J., et. al. (2002). J Immunol. 169(3):1236-40; Bauer, S., et. al. (1999). Science. 285(5428):727-9; Wu, J., et. al. (1999). Science. 285(5428):730-2; Roberts, A.I., et. al. (2001). J Immunol. 167(10):5527-30).
Immunoprecipitation Analysis: A representative lot detected NKG2D (CD314) in Immunoprecipitation applications (Bauer, S., et. al. (1999). Science. 285(5428):727-9).
Anti-NKG2D (CD314), clone 1D11, Cat. No. MABF1032, is a mouse monoclonal antibody that detects human NKG2-D type II integral membrane protein and has been tested for use in Flow Cytometry, Fluorescence Activated Cell Sorting (FACS), Immunohistochemistry, Immunoprecipitation, ECM Adhesion and Inhibit
Quality
Isotype testing: Identity Confirmation by Isotyping Test.
Isotyping Analysis: The identity of this monoclonal antibody is confirmed by isotyping test to be mouse IgG1 .
Target description
25.27 kDa calculated.
Physical form
Format: Purified
Quality Level | 100 |
biological source | mouse |
antibody form | purified immunoglobulin |
antibody product type | primary antibodies |
clone | 1D11, monoclonal |
species reactivity | human |
packaging | antibody small pack of 25 µL |
application(s) | flow cytometry: suitable","immunohistochemistry: suitable","immunoprecipitation (IP): suitable |
isotype | IgG1 |
NCBI accession no. | NP_001186734, |
UniProt accession no. | P26718, |
shipped in | ambient |
WGK Germany | WGK 1 |
Flash Point F | Not applicable |
Flash Point C | Not applicable |
Получите коммерческое предложение в течение 1 часа
Менеджер подготовит коммерческое предложение и позвонит, если понадобится уточнить детали вашего заказа

С 2010 года мы поставляем оборудование с заводов Европы. Берем на себя все — от подбора оборудования до внедрения на предприятии

Все сотрудники имеют высшее образование, закончили ведущие химические вузы страны, такие как РХТУ им Менделеева.

У большинства компаний срок ожидания составляет 10-12 недель.

Оборудование хранится на сухом отапливаемом складе, где поддерживается ровная температура.

Работаем с PonyExpress и Деловыми линиями. Вы также можете выбрать свою транспортную компанию или забрать товар со склада в Москве.

В случае любых неполадок за свой счет выполним ремонт в сервисном центре или на заводе-изготовителе. Или бесплатно заменим прибор на новый.

Производим пуско-наладку оборудования, валидацию, обучение сотрудников. Если нужно, привлекаем инженеров с заводов- изготовителей.