- Производитель:
- Roche
- Quickly determine apoptosis induction for cell-based workflows in life science research.
- Reliably perform screening assays in product development, e.g., cancer research, pre-clinical safety.
- Accurately measure malignant cell sensitivity in cancer research.
Features and Benefits
- Optimized for data evaluation with Roches Cellavista System. Obtain reproducible results using automated imaging with this system.
- Saves time and resources: Total assay time, including analysis, for a 96-well microplate is 85 minutes.
- Reduced risk of losing cells with fewer washing steps in an improved protocol.
Packaging
1 kit containing 3 components
Quality
The kit is function tested using a cellular model (HeLa cells treated with antimycin A).
Principle
Labeling of apoptotic cells
Genomic DNA cleavage during apoptosis produces double-stranded, low molecular weight DNA fragments (mono- and oligonucleosomes), as well as single strand breaks (nicks) in high molecular weight DNA. These DNA strand breaks are identified by labeling free 3-OH termini with modified nucleotides in an enzymatic assay known as the TUNEL reaction. The TUNEL reaction preferentially labels DNA strand breaks generated during apoptosis. TUNEL assays discriminate apoptosis from necrosis, and from primary DNA strand breaks induced by cytostatic drugs or irradiation. The DNA Fragmentation Imaging Kit labels DNA strand breaks using terminal deoxynucleotidyl transferase (TdT). TdT catalyzes polymerization of labeled nucleotides to free 3-OH DNA ends in a template-independent manner using the TUNEL reaction. Fluorescein incorporated in nucleotide polymers is detected and quantified using fluorescence microscopy.
Staining of nuclei
Hoechst 33342 is a cell-permeable stain that binds DNA. It is used to stain nuclei of living or dead cells.
Preparation Note
Storage conditions (working solution): The Reaction Solution created by mixing the Enzyme Solution and Label Solution (Vial 2 and Vial 3), in Step 6 of the experiment protocol, cannot be stored. The Reaction Solution should be prepared just before use. Discard remaining unused Reaction Solution.
Storage and Stability
Store at 15 to 25 °C. (Protect from exposure to light. Store dry in dark.)
Quality Level | 100, |
Торговая марка | Roche |
storage condition | avoid repeated freeze/thaw cycles |
shipped in | dry ice |
pictograms | GHS08,GHS09 |
signalword | Danger |
hcodes | H341 - H350i - H411 |
pcodes | P201 - P273 - P280 - P308 + P313 - P391 - P501 |
RIDADR | UN 1556 6.1 / PGIII |
WGK Germany | WGK 3 |
Flash Point F | does not flash |
Flash Point C | does not flash |
Получите коммерческое предложение в течение 1 часа
Менеджер подготовит коммерческое предложение и позвонит, если понадобится уточнить детали вашего заказа

С 2010 года мы поставляем оборудование с заводов Европы. Берем на себя все — от подбора оборудования до внедрения на предприятии

Все сотрудники имеют высшее образование, закончили ведущие химические вузы страны, такие как РХТУ им Менделеева.

У большинства компаний срок ожидания составляет 10-12 недель.

Оборудование хранится на сухом отапливаемом складе, где поддерживается ровная температура.

Работаем с PonyExpress и Деловыми линиями. Вы также можете выбрать свою транспортную компанию или забрать товар со склада в Москве.

В случае любых неполадок за свой счет выполним ремонт в сервисном центре или на заводе-изготовителе. Или бесплатно заменим прибор на новый.

Производим пуско-наладку оборудования, валидацию, обучение сотрудников. Если нужно, привлекаем инженеров с заводов- изготовителей.