- Производитель:
- Sigma-Aldrich
CAS Number: | 9031-94-1 |
Enzyme Commission (EC) Number: | 3.4.11.22 ( BRENDA | IUBMB ) |
EC Number: | 232-874-6 |
MDL number: | MFCD00166325 |
NACRES: | NA.54 |
Кат. номер |
A9934-.1MG |
A9934-.1MG-PW |
- to test the biochar exposure effect on the enzyme activity
- in circular dichroism (CD) spectroscopy studies
- as a positive control in p-nitroanilide degradation assay
Packaging
0.1 mg in serum bottle
Package size based on protein content.
Biochem/physiol Actions
Aminopeptidase I may also be used as a reagent in the assay of endoprotease activities with a synthetic substrate in a two-stage assay. In the first stage, the endoprotease cleaves a peptide, such as Z-Y-X-Leu-p-nitroanilide, with the X, Y, and Z residues being chosen according to the specificity of the endoprotease.
Aminopeptidase I from S. griseus has a fairly broad specificity, being able to remove the N-terminal residue of most proteins, except where the penultimate residue is an imino acid. It contains two Zn2+ binding sites. Aminopeptidase I from S. griseus is inhibited by 1,10-phenanthroline and is activated six-fold by Ca2+, which also stabilizes it against heat inactivation. This monomeric zinc metalloprotein has an isoelectric point (pI) of 5.4.
Unit Definition
One unit will hydrolyze 1.0 µmole of L-leucine-p-nitroanilide to L-leucine and p-nitroaniline per min at pH 8.0, 25 °C and 3.0 mM substrate concentration.
Physical form
Contains calcium acetate
Preparation Note
Reconstitute in 20 mM tricine, pH 8.0, with 0.05% bovine serum albumin. Dilute the enzyme with the reconstitution buffer to 0.15-0.3 U/mL for a working concentration. Solutions should be prepared fresh prior to use.
form | lyophilized powder |
Quality Level | 200, |
specific activity | 200 units/mg protein |
mol wt | 21 kDa by gel filtration, 33 kDa by SDS-PAGE |
composition | Protein, 40-60% Lowry |
storage temp. | 20°C |
pictograms | GHS07,GHS08 |
signalword | Danger |
hcodes | H315 - H319 - H334 - H335 |
pcodes | P261 - P264 - P271 - P302 + P352 - P304 + P340 + P312 - P305 + P351 + P338 |
Target Organs | Respiratory system |
Personal Protective Equipment | Eyeshields,, Gloves,, type N95 (US), |
RIDADR | NONH for all modes of transport |
WGK Germany | WGK 1 |
Flash Point F | Not applicable |
Flash Point C | Not applicable |
Получите коммерческое предложение в течение 1 часа
Менеджер подготовит коммерческое предложение и позвонит, если понадобится уточнить детали вашего заказа

С 2010 года мы поставляем оборудование с заводов Европы. Берем на себя все — от подбора оборудования до внедрения на предприятии

Все сотрудники имеют высшее образование, закончили ведущие химические вузы страны, такие как РХТУ им Менделеева.

У большинства компаний срок ожидания составляет 10-12 недель.

Оборудование хранится на сухом отапливаемом складе, где поддерживается ровная температура.

Работаем с PonyExpress и Деловыми линиями. Вы также можете выбрать свою транспортную компанию или забрать товар со склада в Москве.

В случае любых неполадок за свой счет выполним ремонт в сервисном центре или на заводе-изготовителе. Или бесплатно заменим прибор на новый.

Производим пуско-наладку оборудования, валидацию, обучение сотрудников. Если нужно, привлекаем инженеров с заводов- изготовителей.