- Производитель:
- Sigma-Aldrich
NACRES: | NA.55 |
Кат. номер |
D7440-100RXN |
D7440-20RXN |
D7440-400RXN |
- for quantitative polymerase chain reaction (qPCR) amplification of HIV-1 RNA that is reverse transcribed and DNA using probes
- in a 2-step RT-qPCR assay for the quantification of reverse transcribed RNA in a study to monitor the activity of licorice in Treg cell differentiation and function
- as a component of the reaction mixture for the detection and amplification of Salmonella sp. and internal amplification control (IAC) pUC 19 plasmid DNA
- as a component of the reaction mixture for the detection of Clostridium difficile by quantitative polymerase chain reaction (qPCR)
Features and Benefits
- Ultimate Convenience. ReadyMixes contain all components necessary for QPCR, simply add fluorescent detection chemistry, primers, and template
- Greater Specificity & Increased Target Yield. JumpStart Taq prevents non-specific amplification and increased target yield
- Maximum Flexibility. Suitable for use with a variety of detection chemistries including molecular probes and double-stranded binding dyes such as SYBR Green I
Packaging
Sigmas Reference Dye for Quantitative PCR is included separately with this ReadyMix for normalization of the reaction data. The dye has a maximum excitation of 586 nm, and a maximum emission of 605 nm. The instrument settings for ROX reference dye are satisfactory for the measurement of the Reference Dye for Quantitative PCR. A tube of 25 mM MgCl2 is also provided for easy optimization of the qPCR reaction.
Default reaction volume is 50 µL
20RXN is packaged as 1 X 500 µL
100RXN is packaged as 1 X 2.5 mL
400RXN is packaged as 1 X 10 mL
Principle
The ReadyMix contains JumpStart Taq DNA Polymerase, 99% pure deoxynucleotides, and buffer in an optimized 2x concentrate. To prepare a reaction, 25 μL of the ReadyMix is added to primers, template, detection chemistry, and water for a total reaction volume of 50 μL. Set up can be performed at room temperature since the JumpStart Taq antibody renders the Taq DNA polymerase inactive. During the first denaturation cycle, the antibody dissociates from the enzyme and full activity is restored. No special preparations or protocol changes are required.
Unit Definition
One unit incorporates 10 nmol of total dNTPs into acid-precipitable DNA in 30 min. at 74 °C.
This product is an Authorized 5 Nuclease Core Kit. Use of this product is covered by one or more of the following claims outside the US corresponding to US Patent No. 5,210,015 and 5,487,972. The purchase of this product includes a limited, non-transferable immunity from suit under the foregoing patent claims for using only this amount of product for the purchasers own internal research. Separate purchase of a Licensed Probe would convey rights under US Patents and corresponding patent claims outside the US: 5,538,848, 5,723,591, 5,876,930, 6,030,787, 6,258,569, 5,804,375 (claims 1-12 only), and and claims outside the United States corresponding to US Patent No. 6,214,979. No right under any other patent claim and no right to perform commercial services of any kind, including without limitation reporting the results of purchasers activities for a fee or other commercial consideration, is conveyed expressly, by implication, or by estoppel. This product is for research use only. Diagnostic uses under Roche patents require a separate license from Roche. Further information on purchasing licenses may be obtained from the Director of Licensing, Applied Biosystems, 850 Lincoln Centre Drive, Foster City, California 94404, USA.
Eppendorf is a registered trademark of Eppendorf AG
JumpStart is a trademark of Sigma-Aldrich Co. LLC
ReadyMix is a trademark of Sigma-Aldrich Co. LLC
Quality Level | 200, |
form | liquid |
feature | hotstart |
concentration | 1.5 units/reaction (50 µL reaction volume) |
application(s) | qPCR: suitable |
color | colorless |
Featured Industry | Agriculture |
compatibility | for use with ABI 5700, for use with ABI 7000, for use with ABI 7300, for use with ABI 7500 Fast, for use with ABI 7500, for use with ABI 7700, for use with ABI 7900 Fast, for use with ABI 7900 HT, for use with ABI 7900, for use with ABI StepOne, for use with ABI StepOnePlus, for use with ABI ViiA 7, for use with Bio-Rad CFX384, for use with Bio-Rad CFX96, for use with Bio-Rad MJ Chromo4, for use with Bio-Rad MJ Opticon 2, for use with Bio-Rad MJ Opticon Cepheid SmartCycler, for use with Bio-Rad MJ Opticon, for use with Bio-Rad MiniOpticon, for use with Eppendorf® Mastercycler ep realplex2 s, for use with Eppendorf® Mastercycler ep realplex, for use with Illumina Eco qPCR, for use with Qiagen Corbett Rotor-Gene 3000, for use with Qiagen Corbett Rotor-Gene 6000, for use with Qiagen Corbett Rotor-Gene Q, for use with Roche LightCycler 480, for use with Strategene Mx3000P, for use with Strategene Mx3005P, for use with Strategene Mx4000 |
detection method | probe-based |
shipped in | wet ice |
storage temp. | 20°C |
RIDADR | NONH for all modes of transport |
WGK Germany | WGK 3 |
Flash Point F | Not applicable |
Flash Point C | Not applicable |
Получите коммерческое предложение в течение 1 часа
Менеджер подготовит коммерческое предложение и позвонит, если понадобится уточнить детали вашего заказа

С 2010 года мы поставляем оборудование с заводов Европы. Берем на себя все — от подбора оборудования до внедрения на предприятии

Все сотрудники имеют высшее образование, закончили ведущие химические вузы страны, такие как РХТУ им Менделеева.

У большинства компаний срок ожидания составляет 10-12 недель.

Оборудование хранится на сухом отапливаемом складе, где поддерживается ровная температура.

Работаем с PonyExpress и Деловыми линиями. Вы также можете выбрать свою транспортную компанию или забрать товар со склада в Москве.

В случае любых неполадок за свой счет выполним ремонт в сервисном центре или на заводе-изготовителе. Или бесплатно заменим прибор на новый.

Производим пуско-наладку оборудования, валидацию, обучение сотрудников. Если нужно, привлекаем инженеров с заводов- изготовителей.