- For qPCR amplifications using SYBR
- For multiplex PCR
- For reduction of primer dimers
Features and Benefits
- To prepare a typical QPCR reaction, mix 25 µL of JumpStart ReadyMix Taq, fluorescent probe, desired amount of magnesium chloride (above 1.5 mM final concentration), template DNA, and primers in a final volume of 50 µL . Reaction volumes can be scaled down, if desired.
- JumpStart Taq DNA polymerase prevents non-specific product formation, and allows assembled PCR reactions to be placed at room temperature for up to two hours without compromising the performance.
- Internal Reference Dye is provided for reaction normalization.
- When performing large numbers of PCR reactions, JumpStart ReadyMix Taq can save a significant amount of preparation time, reduce the risk of contamination from multiple pipetting steps, and provide consistent batch-to-batch and reaction-to-reaction performance.
Packaging
Default reaction volume is 50 µL
20RXN is packaged as 1 X 500 µL
400RXN is packaged as 1 X 10 mL
2000RXN is packaged as 1 X 50 mL
JumpStart Taq ReadyMix for High Throughput Quantitative PCR is a reaction formulation used for high throughput hot-start quantitative PCR methods. It contains the hot start DNA polymerase reaction mixture with ROX dye as an internal reference for normalization of reactions.
Quantity
Use 2.5 units per reaction.
JumpStart is a trademark of Sigma-Aldrich Co. LLC
ReadyMix is a trademark of Sigma-Aldrich Co. LLC
Quality Level | 200, |
form | liquid |
feature | hotstart |
concentration | 2.5 units/reaction (50 µL reaction volume) |
application(s) | qPCR: suitable |
color | colorless |
Featured Industry | Agriculture |
compatibility | for use with ABI 5700, for use with ABI 7000, for use with ABI 7300, for use with ABI 7500 Fast, for use with ABI 7500, for use with ABI 7700, for use with ABI 7900 Fast, for use with ABI 7900 HT, for use with ABI 7900, for use with ABI StepOne, for use with ABI StepOnePlus, for use with ABI ViiA 7, for use with Bio-Rad CFX384, for use with Bio-Rad CFX96, for use with Bio-Rad MJ Chromo4, for use with Bio-Rad MJ Opticon 2, for use with Bio-Rad MJ Opticon Cepheid SmartCycler, for use with Bio-Rad MJ Opticon, for use with Bio-Rad MiniOpticon, for use with Eppendorf® Mastercycler ep realplex2 s, for use with Eppendorf® Mastercycler ep realplex, for use with Illumina Eco qPCR, for use with Qiagen Corbett Rotor-Gene 3000, for use with Qiagen Corbett Rotor-Gene 6000, for use with Qiagen Corbett Rotor-Gene Q, for use with Roche LightCycler 480, for use with Strategene Mx3000P, for use with Strategene Mx3005P, for use with Strategene Mx4000 |
detection method | probe-based |
shipped in | wet ice |
storage temp. | 20°C |
pictograms | GHS03,GHS05,GHS07,GHS09 |
signalword | Danger |
hcodes | H272 - H315 - H317 - H318 - H410 |
pcodes | P210 - P273 - P280 - P302 + P352 - P305 + P351 + P338 + P310 |
RIDADR | UN 3082 9 / PGIII |
Получите коммерческое предложение в течение 1 часа
Менеджер подготовит коммерческое предложение и позвонит, если понадобится уточнить детали вашего заказа

С 2010 года мы поставляем оборудование с заводов Европы. Берем на себя все — от подбора оборудования до внедрения на предприятии

Все сотрудники имеют высшее образование, закончили ведущие химические вузы страны, такие как РХТУ им Менделеева.

У большинства компаний срок ожидания составляет 10-12 недель.

Оборудование хранится на сухом отапливаемом складе, где поддерживается ровная температура.

Работаем с PonyExpress и Деловыми линиями. Вы также можете выбрать свою транспортную компанию или забрать товар со склада в Москве.

В случае любых неполадок за свой счет выполним ремонт в сервисном центре или на заводе-изготовителе. Или бесплатно заменим прибор на новый.

Производим пуско-наладку оборудования, валидацию, обучение сотрудников. Если нужно, привлекаем инженеров с заводов- изготовителей.