- Производитель:
- Roche
Кат. номер |
3531287001 |
3531317001 |
3531295001 |
A recombinant reverse transcriptase for the robust transcription of RNA fragments up to 14 kb used in two-step RT-PCR on thermal cyclers and real-time PCR instruments.
- Synthesis of first-strand cDNA for use in subsequent amplification reactions
- RT-PCR of GC-rich RNA templates
- Cy3, Cy5, DIG, biotin, and aminoallyl labeling during cDNA synthesis
- Retrieving and cloning the 5 and 3 termini of mRNA by RACE
- Generation of cDNA libraries with large inserts
- Dideoxy DNA sequencing
- RNA sequencing
- 3-end labeling of DNA fragments
- Generation of single-stranded probes for genomic footprints
- In the reverse transcription of RNA from human Papillomavirus E6, cortical and striatal tissues, muscle biopsies of Becker muscular dystrophy samples and miRNA stem-loop from oocytes and human cerebral microvascular endothelial cells (hCMVECs)
Biochem/physiol Actions
Human immunodeficiency virus type 1 reverse transcriptase (HIV-1 RT) is essential for the catalytic conversion of single-stranded viral RNA into the double-stranded linear DNA that is integrated into host cell chromosomes.
Features and Benefits
- Achieve high sensitivity in two-step RT-PCR.
- Obtain more full-length transcripts - up to 14 kb.
- Reverse transcribe difficult templates.
- Efficiently label cDNA.
Components
- Transcriptor Reverse Transcriptase, in storage buffer
- Transcriptor RT buffer, 5x concentrated
Quality
Each lot of Transcriptor Reverse Transcriptase is routinely function tested in RT-PCR:
- with a conventional thermal cycler to detect a 10-kb fragment from the human dystrophin gene, starting from human skeletal muscle total RNA
- with the LightCycler® Instrument to detect 5 x 102 to 5 x 106 copies of in vitro-transcribed human PBGD RNA. The results are defined in fixed crossing points and fixed fluorescence intensity.
Preparation Note
Volume activity: 20 U/µl.
Transcription of long, rare, or difficult RNA targets
Transcriptor Reverse Transcriptase is recommended for RT-PCR of:
- long targets, because it can transcribe up to 14 kb RNA templates
- rare targets, because it has high sensitivity
- GC-rich targets, because it can operate at high temperatures (up to +65oC) to eliminate problems associated with extensive secondary structure
Labeling for many applications
Transcriptor Reverse Transcriptase is also recommended for preparing labeled cDNA, since it accepts a wide variety of modified nucleotides (including Cy3-, Cy5-, DIG-, Biotin-, or aminoallyl-labeled dNTPs).
Reaction requirements
Transcriptor accepts ssRNA and ssDNA templates and requires a primer for transcription.
Quality Level | 100, |
Торговая марка | Roche |
packaging | pkg of 200 reactions (03531287001), pkg of 25 reactions (03531317001), pkg of 50 reactions (03531295001) |
application(s) | RT-qPCR: suitable |
detection method | probe-based |
RIDADR | NONH for all modes of transport |
WGK Germany | WGK 1 |
Flash Point F | does not flash |
Flash Point C | does not flash |
Получите коммерческое предложение в течение 1 часа
Менеджер подготовит коммерческое предложение и позвонит, если понадобится уточнить детали вашего заказа

С 2010 года мы поставляем оборудование с заводов Европы. Берем на себя все — от подбора оборудования до внедрения на предприятии

Все сотрудники имеют высшее образование, закончили ведущие химические вузы страны, такие как РХТУ им Менделеева.

У большинства компаний срок ожидания составляет 10-12 недель.

Оборудование хранится на сухом отапливаемом складе, где поддерживается ровная температура.

Работаем с PonyExpress и Деловыми линиями. Вы также можете выбрать свою транспортную компанию или забрать товар со склада в Москве.

В случае любых неполадок за свой счет выполним ремонт в сервисном центре или на заводе-изготовителе. Или бесплатно заменим прибор на новый.

Производим пуско-наладку оборудования, валидацию, обучение сотрудников. Если нужно, привлекаем инженеров с заводов- изготовителей.