- Производитель:
- Millipore
eCl@ss: | 32161000 |
Кат. номер |
HNS2MAG-95K-01 |
HNS2MAG-95K-02 |
HNS2MAG-95K-03 |
HNS2MAG-95K |
HNS2MAG-95K-05 |
HNS2MAG-95K-06 |
HNS2MAG-95K-07 |
HNS2MAG-95K-04 |
MILLIPLEX® Human Neuroscience Bead Panel 2 is a 6-plex kit to be used for the simultaneous quantification of any or all of the following analytes in cerebrospinal fluid (CSF), serum/plasma and cell/tissue culture supernatants for homogenates: Angiogenin, ApoE4, FABP3, Ferritin, Neurogranin, TREM2.
Panel Type: Neuroscience
Cross-reactivity between the antibodies and any of the other analytes in this panel is non-detectable or negligible. There is <5% cross-reactivity from ApoE2 and ApoE3 recombinant proteins on the ApoE4 beads.
- Analytes: Angiogenin, ApoE4, FABP3, Ferritin, Neurogranin, TREM2
- Recommended Sample type: Plasma, Serum, CSF, Cell/Tissue culture supernatant
- For Plasma/Serum a 1:10 dilution is recommended for the optimal detection of the analytes FABP3, Ferritin, Neurogranin and TREM2.
- For Plasma/Serum a 1:200 dilution for ApoE4 and Angiogenin is recommended.
- Because the sample dilutions differ for Plasma/Serum samples ApoE4 and Angiogenin cannot be plexed in the same assay as FABP3, Ferritin, Neurogranin and TREM2.
- CSF samples require a 1:10 dilution and so may all be plexed together
- Cell/Tissue culture supernatants or homogenates may be used neat or diluted in appropriate control medium.
- Bead diluent must be present in order to detect Angiogenin. (Biotinylated-Angiogenin detection antibody is included in the bead diluent.)
- Research Category: Neuroscience
species reactivity | human |
Торговая марка | Milliplex® |
assay range | accuracy: 124% (Neurogranin), accuracy: 84% (FABP3), accuracy: 85% (ApoE4), accuracy: 94% (TREM2), accuracy: 97% (Angiogenin), sensitivity: 11.0 pg/mL (MinDC + 2SD; TREM2), sensitivity: 14.3 pg/mL (MinDC + 2SD; FABP3), sensitivity: 162.8 pg/mL (MinDC + 2SD; ApoE4), sensitivity: 19.9 pg/mL (MinDC + 2SD; Neurogranin), sensitivity: 5.8 pg/mL (MinDC + 2SD; Angiogenin), sensitivity: 6.1 pg/mL (MinDC + 2SD; Ferritin), standard curve range: 15-50,000 pg/mL (TREM2), standard curve range: 2-10,000 pg/mL (Angiogenin), standard curve range: 24-100,000 pg/mL (FABP3), standard curve range: 244-1,000,000 pg/mL (ApoE4), standard curve range: 5-20,000 pg/mL (Neurogranin), standard curve range: 6-25,000 pg/mL (Ferritin), inter-assay cv: <10% intra-assay cv: <5% (Angiogenin), inter-assay cv: <10% intra-assay cv: <5% (FABP3), inter-assay cv: <10% intra-assay cv: <5% (TREM2), inter-assay cv: <15% intra-assay cv: <10% (Ferritin), inter-assay cv: <15% intra-assay cv: <10% (Neurogranin), inter-assay cv: <15% intra-assay cv: <5% (ApoE4) |
application(s) | multiplexing: suitable |
detection method | fluorometric (Luminex xMAP) |
Получите коммерческое предложение в течение 1 часа
Менеджер подготовит коммерческое предложение и позвонит, если понадобится уточнить детали вашего заказа

С 2010 года мы поставляем оборудование с заводов Европы. Берем на себя все — от подбора оборудования до внедрения на предприятии

Все сотрудники имеют высшее образование, закончили ведущие химические вузы страны, такие как РХТУ им Менделеева.

У большинства компаний срок ожидания составляет 10-12 недель.

Оборудование хранится на сухом отапливаемом складе, где поддерживается ровная температура.