- routine polymerase chain reaction (PCR)
- multiplex PCR
- rapid photo PCR samples
- Fast PCR
- genotyping
Biochem/physiol Actions
DNA fragments produced with KAPA2G Fast DNA Polymerase share the same characteristics as DNA fragments generated with wild-type Taq DNA polymerase and may be used for routine downstream analyses or applications, including restriction enzyme digestion, cloning and sequencing. Like wild-type Taq, KAPA2G Fast has 53 polymerase and 53 exonuclease activities, but no 35 exonuclease (proofreading) activity. The fidelity of KAPA2G Fast is similar to that of wild-type Taq; it has an error rate of approximately 1 error per 1.7 x 105 nucleotides incorporated.
Features and Benefits
Reduce cycling times up to 75% :
- Extension times as low as 1 sec per kilobase
- Broad coverage of both AT- and GC-rich targets
High speed, higher performance :
- Single copy sensitivity from complex targets
- Increased yields
Quick Notes :
- KAPA2G Fast PCR Kits contain the engineered KAPA2G Fast DNA Polymerase, developed for fast PCR.
- Use 1 sec extension time for amplicons <1 kb and 15 sec/kb for longer amplicons, and save 20–70% of total reaction time.
- No need for specialized instrumentation or PCR consumables.
- Optimized buffer system offers improved yields, specificity and sensitivity, facilitating efficient primer annealing across a wide range of primer lengths, GC contents, and melting temperatures.
- Use 0.5 U KAPA2G Fast DNA Polymerase per 25 µL reaction, or less for smaller volumes.
- For high reaction efficiency, do not exceed 25 µL reaction volumes.
- KAPA2G Buffer A contains 1.5 mM MgCl2 at 1X.
- Reaction products are 3-dA-tailed and may be cloned into TA cloning vectors.
Quality
Each batch of KAPA2G Fast DNA Polymerase is confirmed to contain <2% contaminating protein (Agilent Protein 230 Assay). KAPA2G Fast ReadyMix is subjected to stringent quality control tests, is free of contaminating exo- and endonuclease activity, and meets strict requirements with respect to DNA contamination levels.
Preparation Note
Always ensure that the product has been fully thawed and mixed before use. Reagents may be stored at 4°C for short-term use (up to 1 month). Return to -20°C for long-term storage. Provided that all components have been handled carefully and not contaminated, the kit is not expected to be compromised if left (unintentionally) at room temperature for a short period of time (up to 3 days). Long-term storage at room temperature and 4°C is not recommended. Please note that reagents stored at temperatures above -20°C are more prone to degradation when contaminated during use, and therefore storage at such temperatures is at the users own risk.
Quality Level | 100, |
shelf life | 18 mo. |
feature | Fast PCR, Multiplex PCR, dNTPs included: no, hotstart: no |
packaging | pkg of 100 U (KK5020), pkg of 250 U (KK5021) |
Торговая марка | Roche |
application(s) | PCR: suitable |
input | purified DNA |
shipped in | dry ice |
storage temp. | 20°C |
pictograms | GHS07,GHS08 |
signalword | Warning |
hcodes | H302 - H371 - H412 |
pcodes | P260 - P264 - P270 - P273 - P308 + P311 - P501 |
RIDADR | NONH for all modes of transport |
WGK Germany | WGK 1 |
Flash Point F | does not flash |
Flash Point C | does not flash |
Получите коммерческое предложение в течение 1 часа
Менеджер подготовит коммерческое предложение и позвонит, если понадобится уточнить детали вашего заказа

С 2010 года мы поставляем оборудование с заводов Европы. Берем на себя все — от подбора оборудования до внедрения на предприятии

Все сотрудники имеют высшее образование, закончили ведущие химические вузы страны, такие как РХТУ им Менделеева.

У большинства компаний срок ожидания составляет 10-12 недель.

Оборудование хранится на сухом отапливаемом складе, где поддерживается ровная температура.

Работаем с PonyExpress и Деловыми линиями. Вы также можете выбрать свою транспортную компанию или забрать товар со склада в Москве.

В случае любых неполадок за свой счет выполним ремонт в сервисном центре или на заводе-изготовителе. Или бесплатно заменим прибор на новый.

Производим пуско-наладку оборудования, валидацию, обучение сотрудников. Если нужно, привлекаем инженеров с заводов- изготовителей.