- Производитель:
- Sigma-Aldrich
Кат. номер |
ZRB1384-4X25UL |
ZRB1384-25UL |
Each ZooMAb® antibody is manufactured using our proprietary recombinant expression system, purified to homogeneity, and precisely dispensed to produce robust and highly reproducible lot-to-lot consistency. Only top-performing clones are released for use by researchers. Each antibody is validated for high specificity and affinity across multiple applications, including its most commonly used application. ZooMAb® antibodies are reliably available and ready to ship when you need them.
Evaluated by Western Blotting in Human prostate tissue lysate.
Western Blotting Analysis: A 1:10,000 dilution of this antibody detected ALK-7 in Human prostate tissue lysate.
Tested applications
Immunocytochemistry Analysis: A 1:100 dilution from a representative lot detected ALK-7 in PC3 cells.
Flow Cytometry Analysis: 1 µg from a representative lot detected ALK-7 in one million PC3 cells.
Affinity Binding Assay: A representative lot of this antibody bound ALK-7 Peptide with a KD of 1.0 x 10-12 in an affinity binding assay.
Note: Actual optimal working dilutions must be determined by end user as specimens, and experimental conditions may vary with the end user
Anti-ALK-7, clone 1N5 ZooMAb®, Cat. No. ZRB1384, is a recombinant Rabbit monoclonal antibody that specifically targets ALK-7 and is tested for use in Affinity Binding Assay, Flow Cytometry, Immunocytochemistry, and Western Blotting.
Target description
Activin receptor type-1C (UniProt: Q8NER5, also known as EC:2.7.11.30, Activin receptor type IC, ACTR-IC, Activin receptor-like kinase 7, ALK-7) is encoded by the ACVR1C (also known as ALK7) gene (Gene ID: 130399) in human. ALK-7 is a single-pass type I membrane protein that is synthesized with a signal peptide (aa 1-20) that is subsequently cleaved off to generate the mature form that contains an extracellular domain (aa 21-113), a transmembrane domain (aa 114-134, and a cytoplasmic domain (aa 135-493). ALK-7 expression is reported in pancreas, heart, colon, small intestine, ovary and the hippocampus, medulla oblongata and putamen of the brain. It serves as a transmembrane type IC receptor serine kinase for activin or activin-like ligands. The receptor complex consists of 2 type II and 2 type I transmembrane serine/threonine kinases. Type II receptors phosphorylate and activate type I receptors which auto-phosphorylate, then bind and activate SMAD transcriptional regulators, SMAD2 and SMAD3. The type I receptors contains a Ser/Thr kinase domain in its cytoplasmic domain (aa 194-485) that is essential for signaling, while the type II are receptors are essential for ligand binding. ALK-7 is reported to negatively regulate glucose-stimulated insulin release in -cells. Mice lacking ALK-7 display normal pancreas organogenesis but develop an age-dependent syndrome involving progressive hyperinsulinemia, reduced insulin sensitivity, liver steatosis, impaired glucose tolerance, and islet enlargement. This ZooMAb® recombinant monoclonal antibody, generated by our propriety technology, offers significantly enhanced specificity, affinity, reproducibility, and stability over conventional monoclonals. (Ref.: Roberts, HJ., et al. (2003). Biol. Reprod. 68(5); 1719-1726).
Physical form
Purified recombinant rabbit monoclonal antibody IgG, lyophilized in PBS, 5% Trehalose, normal appearance a coarse or translucent resin. The PBS/trehalose components in the ZooMAb formulation can have the appearance of a semi-solid (bead like gel) after lyophilization. This is a normal phenomenon. Please follow the recommended reconstitution procedure in the data sheet to dissolve the semi-solid, bead-like, gel-appearing material. The resulting antibody solution is completely stable and functional as proven by full functional testing. Contains no biocide or preservatives, such as azide, or any animal by-products. Larger pack sizes provided as multiples of 25 μL.
Reconstitution
300 μg/mL after reconstitution at 25 μL per vial. Please refer to guidance on suggested starting dilutions and/or titers per application and sample type.
Storage and Stability
Recommend storage of lyophilized product at 2-8°C; Before reconstitution, micro-centrifuge vials briefly to spin down material to bottom of the vial; Reconstitute each vial by adding 25 μL of filtered lab grade water or PBS; Reconstituted antibodies can be stored at 2-8°C, or -20°C for long term storage. Avoid repeated freeze-thaws.
Disclaimer
Unless otherwise stated in our catalog or other company documentation accompanying the product(s), our products are intended for research use only and are not to be used for any other purpose, which includes but is not limited to, unauthorized commercial uses, in vitro diagnostic uses, ex vivo or in vivo therapeutic uses or any type of consumption or application to humans or animals.
Quality Level | 200 |
biological source | rabbit |
recombinant | expressed in HEK 293 cells |
antibody form | purified antibody |
antibody product type | primary antibodies |
clone | 1N5, recombinant monoclonal |
description | recombinant, expressed in HEK 293 cells |
product line | ZooMAb® |
form | lyophilized |
mol wt | calculated mol wt 54.87 kDa","observed mol wt ~61 kDa |
species reactivity | human |
species reactivity (predicted by homology) | monkey |
packaging | antibody small pack of 25 µL |
enhanced validation | recombinant expression |
application(s) | affinity binding assay: suitable","flow cytometry: suitable","immunocytochemistry: suitable","western blot: suitable |
isotype | IgG |
epitope sequence | N-terminal half |
conjugate | unconjugated |
Protein
Пуско-наладка
Выполним распаковку, визуальную проверку, сборку и установку, запуск и настройку, проверку функциональности, проведем инструктаж персонала.
Техническое обслуживание
Проведем периодические регламентные работы: визуальный осмотр, очистка засоренных узлов и частей, замена расходных материалов и изношенных деталей, тестирование прибора, проверка показателей и измерение параметров, калибровка и настройка, обновление программного обеспечения.
IQ/OQ/PQ квалификация, валидация
Проведем монтажную (IQ), операционную (OQ) и эксплуатационную (PQ) квалификацию оборудования по протоколам производителя в полном соответствии с стандартами GMP/GLP.
Ремонт
Проведем диагностику в нашем сервисном центре или у Вас на предприятии, выявим причину поломки, устраним неисправность, проведем тестирование, настройку, калибровку отремонтированного оборудования.
Получите коммерческое предложение в течение 1 часаМенеджер подготовит коммерческое предложение и позвонит, если понадобится уточнить детали вашего заказа ![]()
Анна Гловацкая
Менеджер по работе с клиентами
С 2010 года мы поставляем оборудование с заводов Европы. Берем на себя все — от подбора оборудования до внедрения на предприятии![]() Все сотрудники имеют высшее образование, закончили ведущие химические вузы страны, такие как РХТУ им Менделеева. ![]() У большинства компаний срок ожидания составляет 10-12 недель. ![]() Оборудование хранится на сухом отапливаемом складе, где поддерживается ровная температура. ![]() Работаем с PonyExpress и Деловыми линиями. Вы также можете выбрать свою транспортную компанию или забрать товар со склада в Москве. ![]() В случае любых неполадок за свой счет выполним ремонт в сервисном центре или на заводе-изготовителе. Или бесплатно заменим прибор на новый. ![]() Производим пуско-наладку оборудования, валидацию, обучение сотрудников. Если нужно, привлекаем инженеров с заводов- изготовителей. ОтзывыВ числе наших клиентов организации
|