Because the reagent does not contain universally proteolytic enzymes it may not release all cell/tissue types uniformly. Some optimization of cell type and passage number, as well as, incubation time and reagent strength typically needs to be performed to optimize the reagents effectiveness.
ACCUTASE has been shown to be effective on a wide variety of cell types including: fibroblasts, keratinocytes, vascular endothelial cells, hepatocytes, vascular smooth muscle cells, hepatocyte progenitors, primary chick embryo neuronal cells, bone marrow stem cells, adherent CHO and BHK cells, macrophages, 293 cells, L929 cells, immortalized mouse testicular germ cells, 3T3, Vero, COS, HeLa, NT2, MG63, M24 and A375 metastatic melanoma, gliomas U251 and D54, HT1080 fibrosarcoma cells, and Sf9 insect cells.
Each lot of ACCUTASE is tested for Sterility (by USP membrane filtration method), enzymatic activity (tested with synthetic chromagenic tetrapeptides) and cell detachment from tissue culture plastic.
1. Thaw ACCUTASE® at room temperature.
2. Wash plate, flask or beads with sterile PBS.
3. Add ACCUTASE to culture dish or flask using aseptic procedures at 10 ml per 75-cm2 surface area.
4. Return culture to 37°C incubator and allow cells to detach (5-10 minutes).
5. Count cells and passage as usual. No additional washes or enzyme inhibitors are required
Optimal incubation times and reagent strength needs to be determined for each cell/tissue type tested by the enduser.
CHEMICON is a registered trademark of Merck KGaA, Darmstadt, Germany
Quality Level | 300 |
form | liquid |
Торговая марка | Chemicon® |
input | sample type cardiac stem cell(s) sample type hematopoietic stem cell(s) sample type pancreatic stem cell(s) sample type: human embryonic stem cell(s) sample type epithelial cells sample type neural stem cell(s) sample type: mouse embryonic stem cell(s) sample type mesenchymal stem cell(s) sample type induced pluripotent stem cell(s) |
shipped in | dry ice |
WGK Germany | WGK 2 |
Flash Point(F) | Not applicable |
Flash Point(C) | Not applicable |
Получите коммерческое предложение в течение 1 часа
Менеджер подготовит коммерческое предложение и позвонит, если понадобится уточнить детали вашего заказа

С 2010 года мы поставляем оборудование с заводов Европы. Берем на себя все — от подбора оборудования до внедрения на предприятии

Все сотрудники имеют высшее образование, закончили ведущие химические вузы страны, такие как РХТУ им Менделеева.

У большинства компаний срок ожидания составляет 10-12 недель.

Оборудование хранится на сухом отапливаемом складе, где поддерживается ровная температура.

Работаем с PonyExpress и Деловыми линиями. Вы также можете выбрать свою транспортную компанию или забрать товар со склада в Москве.

В случае любых неполадок за свой счет выполним ремонт в сервисном центре или на заводе-изготовителе. Или бесплатно заменим прибор на новый.

Производим пуско-наладку оборудования, валидацию, обучение сотрудников. Если нужно, привлекаем инженеров с заводов- изготовителей.