- Производитель:
- Sigma-Aldrich
Geling is heavily influenced by the pH value. Before starting work, pre-cool all reagents to a temperature of +2 - +8C.
Solution A:
0.7 M sodium hydroxide and 1 M HEPES buffer are mixed equally (e.g. 5 ml sodium hydroxide with 5 ml HEPES buffer).
Solution B:
A 10x medium (e.g. RPMI 1640) and solution A are mixed equally (e.g. 5 ml medium with 5 ml solution A).
- The pH of solution B should be between 7.90 and 8.05. It is advisable to check the pH using a suitable measuring method. If the gel should remain sterile, measure the pH of an aliquot previously removed.
- 8.0 ml Collagen G is gently mixed with 2.0 ml of solution B to produce the ready-to-use solution for gelling. This prevents the formation of air bubbles.
- 3.0 ml of solution prepared in this way is pipetted into a 25 cm2 culture flask. For a culture flask with a diameter of 9 cm, 5.0 ml is required. The culture flask is then incubated vibration-free for at least 1 hour or, for optimum stability, 24 hours at +35°C (± 2°C).
Examining the gel produced under a microscope and taking pictures
If a 35 mm culture dish is filled with 2 ml Collagen G/buffer media mixture (pH approx. 7.2 - 7.8) and incubated, a gel with faint white diffusion is formed, viewed from above. This diffusion appears as a result of crosslinking of the collagen molecules and should not cause any problems when examining under a microscope or taking pictures.
The accumulation of diffusion is proportional to the increase of thickness of the gel, for example if 5-7 ml instead of 2 ml per 10 cm2 Collagen G (35 mm culture vessel) is used. This could make microscopic and photographic analysis difficult.
Cell Attachment: Pass
pH: 1.8-2.4
Osmolality: 0.01-0.05 Osm/kg H20
Collagen Content: 0.37-0.45%
Hydroxyproline: 0.046-0.0565%
Color: Colorless
Appearance: Clear
Quality Level | 200, |
biological source | bovine (calf) skin |
form | liquid |
packaging | 100 mL of |
concentration | 4 mg/mL |
application(s) | cell culture | mammalian: suitable |
shipped in | ambient |
storage temp. | 2-8°C |
WGK Germany | nwg |
Flash Point F | Not applicable |
Flash Point C | Not applicable |
Получите коммерческое предложение в течение 1 часа
Менеджер подготовит коммерческое предложение и позвонит, если понадобится уточнить детали вашего заказа

С 2010 года мы поставляем оборудование с заводов Европы. Берем на себя все — от подбора оборудования до внедрения на предприятии

Все сотрудники имеют высшее образование, закончили ведущие химические вузы страны, такие как РХТУ им Менделеева.

У большинства компаний срок ожидания составляет 10-12 недель.

Оборудование хранится на сухом отапливаемом складе, где поддерживается ровная температура.

Работаем с PonyExpress и Деловыми линиями. Вы также можете выбрать свою транспортную компанию или забрать товар со склада в Москве.

В случае любых неполадок за свой счет выполним ремонт в сервисном центре или на заводе-изготовителе. Или бесплатно заменим прибор на новый.

Производим пуско-наладку оборудования, валидацию, обучение сотрудников. Если нужно, привлекаем инженеров с заводов- изготовителей.